title: Manage
slug: edgemanager/lem-user-ui/product-features/edge-devices/edge-device-details/manage
description: Review management options for activated edge devices.
docTags: 
createdAt: 2022-08-02T17:55:55.000Z
---

The **Manage** tab for an edge device enables you to:

- Stop and restart specific services.
- Enable or disable log forwarding to Litmus Edge Manager.
- Enable and configure how frequently Litmus Edge Manager polls the edge device for metrics.
- Change the token for direct access to the Litmus Edge API.
- Update the device from a specific version of Litmus Edge.
- Reboot the device.
- Download a support bundle for the device.

# Stop and Restart Services

In the **Service** tab, optionally start and stop the **SSH** service and restart device management, authentication, licensing, and NATS server services.

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/4YdndmEEOVKpqXZdiz0j3_image.png)

# Edge Device Metrics Sync Interval

Edge Device Metrics Sync controls how often LEM polls connected edge devices for metrics data. Adjusting the interval lets you balance reporting frequency against network and performance constraints. A shorter interval provides more granular visibility into edge device behavior. A longer interval reduces network load in bandwidth-limited environments.

### Sync Interval Priority

The sync interval can be configured at three levels: device, project and instance. By default, lower-level settings take priority:

- The device sync setting overrides the project setting for that device.
- The project sync setting overrides the instance setting for all devices in the project.

You can also override these priority settings:

- Here at the device level by choosing to use the project's metrics sync settings (see [Manage](docId\:BoOFh2bJOlfpger0QymmF) ).
- At the project level by choosing to use the instance's metrics sync settings (see [Management](docId\:VzYNhoUsLtjETO0F1aFa1)).

:::hint{type="info"}
**Note**: **Edge Device Metrics Sync Settings** is available for Litmus Edge Manager version 2.26.1 and later.&#x20;
:::

### Set the Edge Device Metrics Sync Interval

The default interval is 30 seconds with a valid range of `30` to `604,800` seconds (1 week).

::Image[]{src="https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/cNH6gbFLFXvTXEu1BIOUT_image.png" size="80" width="1213" height="463" position="flex-start" darkWidth="1213" darkHeight="463" showCaption="false"}

Do any of the following:

- Use the **Enable Edge Device Metrics Sync** toggle to enable or disable synchronization of metrics.
- Update the sync interval for the device by providing a new value in **Enable Edge Device Metrics Sync**.
- To instead use the interval defined by the project, select **Use the project's edge device metrics sync settings**.

# API

Change the token for direct access to Litmus Edge API. See [Tokens](#) to create an API Token. When creating the API token, you cannot make it read-only from the Litmus Edge user interface.

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/QB652oWuSORrC7WF3m4qo_image.png "API sub-tab")

# Software

View the list of downloaded update files for the edge device.&#x20;

From the **Action menu**, you have the following options:&#x20;

- Manually upgrade the edge device from the update file.&#x20;
- Delete the update file.&#x20;

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/k_Zk-RLHu1G6LzQNaupnF_image.png "Software sub-tab")

# Reboot

Reboot the edge device.

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/tMN0NU4FJYR5MXLSi81Nq_image.png "Reboot sub-tab")

# Support

Download support bundle files for the edge device.&#x20;

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/vw8kbZe1ThkZ1-0rRCclc_image.png "Support sub-tab")