Litmus Edge 3.11.3
3 min
release date march 28, 2023 review the current list of limitations docid ptljws rryflbdqgr3ly new features description integration the cognite connector is now available enhancements and improvements description devicehub fragmented writing is now supported for the dnp3 ethernet driver the following enhancements have been made to the roc800 ethernet driver timestamps are now displayed in iso 8601/rfc3339 format with time zone offset the local time is now used for data and time data points the table parameter properties have been updated to avoid incorrect values from being entered the count tag parameter is now available for the jtekt toyopuc cmp link ethernet (gen1) driver you can now download the default certificate for the osi agent advanced driver values entered for the address are now validated against allowed minimum and maximum address values integration all datetime related fields for the aveva datahub connector are now formatted to iso 8601 flows manager when a flows manager is in a warning status, you can now start and stop the flows manager as needed digital twins you can now create an array transformation within a model resolved issues description devicehub fixed issue with not being able to configure decimal point values for the polling interval parameter fixed issue with the bacnetip driver showing a connected status even though the ethernet cable is disconnected fixed issue with the fanuc cnc ethernet (gen1) driver not being able to read values from the x, y, and z axis fixed issue with devicehub metrics displaying an incorrect status for device online status fixed issue with not being able to configure positive float values for tag poll intervals fixed issue with devices showing a polling status for several minutes when visiting the page for the first time fixed issue with the enron modbus driver parsing time incorrectly fixed issue with the compactlogix ethernet advanced driver using the "tagname" parameter instead of "name" to poll data fixed issue with the siemens s7 driver crashing when an incorrect tag address is configured fixed issue with the opc ua client driver displaying duplicate value types digital twins fixed issue with templates not successfully enabling the flatten hierarchy option for instances fixed issue with changes in instances not being applied successfully fixed issue with static attributes not loading successfully from a csv upload fixed issue with not being able to remove a schemaid transformation from a dynamic attribute system fixed issue with the badgerdb database causing slowdowns in performance flows manager fixed issue with the flows manager not automatically restarting when a flow crashes integration fixed issue with litmus edge generating an excessive number of connections to confluent