title: Send Data to Azure IoT Hub with an SAS Key
slug: litmusedge/how-to-guides/integration-guides/azure-iot-hub/send-data-to-azure-iot-hub-with-sas-key
description: Learn how to send data to Azure IoT Hub with an SAS key. 
docTags: 
createdAt: 2022-11-24T18:16:59.000Z
---

Review the following guide for setting up an outbound data integration between Litmus Edge and Azure IoT Hub using an SAS Key.&#x20;

# Before You Begin

You must first [Set up an Azure IoT Hub](docId\:Uaw77-If2Eys0LMB_Xtx1).&#x20;

# Step 1: Add a Device

Follow the steps to [Connect a Device](docId:3eyAfPpweuVmBLCEy17sq). The device will be used to store tags that will be eventually used to create outbound topics in the connector. Make sure to select the **Enable Data Store** checkbox.&#x20;

# Step 2: Add Tags

After connecting the device in Litmus Edge, you can [Add Tags](docId:8sE7z3PmRfwL1nmzcwaLX) to the device. Create tags that you want to use to create outbound topics for the connector.&#x20;

# Step 3: Add the Azure IoT Hub using SAS Key Connector

Follow the steps to [Add a Connector](docId\:ytsWGWeU6H6oEUnHj5hW3) and select the **MQTT - Azure IoT Hub using SAS Key** provider.&#x20;

Configure the following parameters.&#x20;

- **Name**: Enter a name for the connector.&#x20;
- **Hostname**: Enter the IP address or server FQDN of the MQTT broker (must be reachable from your edge device).&#x20;
- **Port**: The MQTT broker's port number. The default value is 8883.&#x20;
- **Client ID**: Copy the *Device ID* of your edge device from th&#x65;*&#xA0;IoT Devices* page in the Azure portal and paste it here.
- **SAS Key**: Copy the primary or secondary shared access key from the *IoT Devices* page in the Azure portal and paste it here.&#x20;
- **Parallel Publish Count**: The maximum number of concurrently published messages. The default value is 16.&#x20;
- **Integration Topic**: The default topic to publish or subscribe to: devices/\[deviceId]/messages/events/. Replace `[deviceId]` with the Device ID copied from Azure.&#x20;
- **Token TTL**: The token expiry time in minutes. The default value is 1440.&#x20;
- **LWT Topic**: The topic for MQTT's Last Will and Testament feature.&#x20;
- **LWT payload**: The payload for MQTT's Last Will and Testament feature.&#x20;
- **LWT payload type**: The payload type for MQTT's Last Will and Testament feature. The options are *string&#x20;*&#x61;nd *base64*.&#x20;
- **LWT QoS**: The Quality of Service value for MQTT's Last Will and Testament feature.&#x20;
- **LWT retained**: Select this check box to retain the value for MQTT's Last Will and Testament feature.&#x20;
- **Throttling Limit**: The maximum number of messages per second to be processed. The default value is zero, which means that there is no limit.&#x20;
- **Persistent storage**: When enabled, this will cause messages to undergo a store-and-forward procedure. Messages will be stored within Litmus Edge when cloud providers are online. &#x20;
- **Queue Mode**: Select the queue mode as **lifo&#x20;**(last in first out) or **fifo&#x20;**(first in first out). Selecting **lifo&#x20;**&#x6D;eans that the last data entry is processed first, and selecting **fifo&#x20;**&#x6D;eans the first data entry is processed first.&#x20;

# Step 4: Enable the Connector

After adding the connector, click the toggle in the connector tile to enable it.&#x20;

::Image[]{src="https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/RQot-5j1JSnlVxY_dW-ZT_azureiotsas.png" size="60" width="369" height="345" position="center" showCaption="false"}

If you see a *Failed&#x20;*&#x73;tatus, you can review the [Connector Logs](docId\:BEQQ0sSzwsv9v9rIF3rhk) and relevant error messages.&#x20;

# Step 5: Create Outbound Topics for Connector

You will now need to create topics from the tags you added in Step 2. &#x20;

Before creating the topics copy the *Raw Topic* parameter for all tags you want to use for topics. See [Manage Tags](docId\:qm0urCLtmYSiMHM2_5kMx) for more information.

**To create topics:**

1. Click the connector tile.
   The connector *Dashboard&#x20;*&#x61;ppears.&#x20;
2. Click the **Topics&#x20;**&#x74;ab.&#x20;
3. Add topics to the connector with the details below. See [Add Topics to Connectors](docId\:B9qPfvffO0YM-BmuNKmUp) for more information.&#x20;
   - **Data Direction**: Select **Local to Remote - Outbound**.&#x20;
   - **Local Data Topic**: Paste th&#x65;*&#x20;Raw Topic* for the tag created in Step 2.&#x20;
   - **Remote Data Topic**: Verify the format of the remote data topic is **devices/\[DeviceID]/messages/events/**. Replace \[DeviceID] with the Device ID parameter configured for the connector.  **devices/MyDevice/messages/devicebound/%24.to=%2Fdevices%2Fmessages%2Fdevicebound**.
   - **Enable**: Click the toggle to enable the topic.&#x20;
4. Click **Yes&#x20;**&#x74;o add the topic.&#x20;
5. After adding all required topics, navigate to the *Integration&#x20;*&#x70;ane.&#x20;
6. From the connector tile, ensure the connector is not disabled and still shows a CONNECTED status.&#x20;

# Step 6: Manage Data in Azure

Once data is sent to the Azure IoT Hub, you can manage it as needed. Refer to the [Azure IoT Hub Documentation](https://learn.microsoft.com/en-us/azure/iot-hub/) to learn more.&#x20;