- Allen-Bradley CompactLogix Ethernet Advanced and Allen-Bradley Logix Ethernet: Renamed the Access Mode option from CompactLogix to Logical. Logical mode now uses ID-based requests for FlexLogix, CompactLogix, and ControlLogix PLCs for all firmware versions. The Global variables folder is now pinned to the top of the browse results.
- Improved AB DF1 Ethernet driver browse and datatype support. Default datatypes are now correctly assigned during browse for Output, Input, Integer, ASCII, and Hex/BCD registers. Added INT datatype support for Output, Input, Timer, Counter, Control, and Register data files.
- Improved B&R PVI Ethernet driver performance. The driver has been optimized to reliably support up to 10,000 tags to enable high-density deployments with large B&R PLC installations.
- Improved CODESYS v2 Symbolic (Gen1.3) driver. Fixed connectivity issues, added support for browsing devices with or without SYM/SDB files, and introduced user-configurable options for Motorola byte order and protocol settings.
- Improved EUROMAP 63 driver session file handling to automatically clean up .REQ files when the controller does not respond to prevent shared folder clutter.
- Added float data type support for the GE Ethernet Absolute driver. R, AI, AQ, and W registers now support float data types to enable accurate reading of floating-point values from GE PLCs.
- Added password authentication support for the S7CommPlus driver. PLCs configured with legacy access control in TIA Portal can now be connected by specifying a password in the device settings. Device settings have also been reorganized with advanced options moved to a collapsible section for a cleaner configuration experience.
- Improved Toyopuc Ethernet driver addressing for bit registers. bit (boolean) tags now use discontinuous addressing, requiring both a Word and Bit address component to match PLC programming software conventions. Existing configurations are automatically migrated during upgrade.
- Improved other Toyopuc Ethernet driver issues. Fixed read/write issues for EB register addresses above 32767, corrected maximum address ranges across multiple register types to align with PLC specifications, and added support for JL and JS registers (PC10G Nano).
- Improved Toyopuc Ethernet driver file name configuration with updated values (P1, P2, and P3) in the File Number dropdown selector.
- Added User ID configuration to the Yokogawa DX Ethernet driver to support communication with controllers that require user authentication.
- Fixed inconsistent field ordering in driver configuration settings. Device and tag settings fields across multiple drivers (including Allen-Bradley, Siemens, GE, Yokogawa, and others) now display in a consistent and predictable order.
- A new count field is available at the tag level for all register types to enable batch reads of consecutive registers as arrays. Added array read support for the following drivers:
- Added data type support for the Generator driver. The following data types are now available: bool, int32, float32, uint32, and json.
- Added tag browsing support for the PLC5 driver.
- Improved AutomationDirect Productivity Series Ethernet driver polling performance by implementing request grouping, reducing the number of requests needed to read tags.
- The following drivers now display a deprecation warning indicating they will be removed in a future release: Mitsubishi QJ71E71, OSI Agent, Allen-Bradley CompactLogix Ethernet FreeTag, and Allen-Bradley CompactLogix Ethernet Advanced.
- Added help text for the Name and Tag Name fields in tag settings to describe their purpose and usage.
- Renamed the Optional Parameters section to Advanced Parameters in the Connect Device and Edit Device dialogs.
- Added help text for the following Generic Device driver tag settings fields to clarify expected values: Payload, Value Length, Response Terminator, and Response Max Length.
- Configuration field tooltips are now displayed in the Create and Edit Subscription dialogs.
|