The Message Counter counts how many messages pass through it during an interval and emits a summary at the end of each interval. Use it to measure message throughput, such as the number of readings a device sends per minute.
How it works
The processor counts every incoming message and emits a summary message when the interval ends. The Mode parameter sets what defines an interval.
Modes
- internal uses a built-in timer to define the interval. Set the interval with Timer Interval Value and Timer Interval Type. Enable Align To Clock to align interval boundaries to the system clock, so a one-minute interval fires at :00, :01, and so on.
- external lets an input wire control the counter. Name the wire measure to emit a summary and reset the count, or name it report to emit a summary without resetting.
Output fields
Each summary message contains the following fields:
- count: the number of messages received in the interval.
- timestamp: the time the summary was emitted, in milliseconds since epoch.
- intervalStart: the start of the counting interval, in milliseconds since epoch.
Parameters
Note: The Timer Interval Value, Timer Interval Type, and Align To Clock settings apply only in internal mode. In external mode, the wire names measure and report control when the counter emits and resets.
Parameters | Details |
|---|---|
Mode | The interval source: internal for the built-in timer, or external for control messages. |
Timer Interval Value | The interval duration, used in internal mode. Default is 1. |
Timer Interval Type | The interval units, used in internal mode: seconds, minutes, or hours. Default is minutes. |
Align To Clock | Aligns ticks to clock boundaries, so a one-minute interval fires at :00, :01, and so on. |