QuickStart Guide
...
Allen-Bradley
Gen 1 Drivers

AB CompactLogix (Gen1)

7min

Important: This driver was deprecated in Litmus Edge version 3.5.2. We recommend using the Gen 2 AB CompactLogix Ethernet FreeTag.

Review the following information for setting up and configuring the AB CompactLogix (Gen1) driver.

Litmus Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Ethernet

Validated devices/series

Replaced with Gen 2 driver

To set up and configure this device in Litmus Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Litmus Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.

To configure your device:

1. Note down the following information and refer to it when needed.

Device: AB CompactLogix L24ER-QB1B

Communication I/F: Ethernet, USB. Refer to the following figure.

Reference image of device
Reference image of device


2. Connect the device to a PC using a USB port.

3. Launch Rockwell's driver configuration tool, RXLinx classic, and add the SmartGuard USB driver.

4. Right-click the device and configure the module.

Network parameters section
Network parameters section


5. Add driver: EtherNet/IP device.

6. Choose adapter: make sure it's the same subnet as the device.

7. Detect the device.

Device detection option
Device detection option


Step 2: Set up the PLC Device in Litmus Edge DeviceHub



Parameter

Value

Type

Allen-Bradley

Driver

AB CompactLogix (Gen1)

Network address

The device address you defined during Step 1

Port

44818

Slot Number

0

Step 3: Configure the List of Registers

When you Add Tags to the connected device, use the following tag/register mapping table.

Note

  • The Browse icon displayed on the device tile means that this PLC uses Browse Tags. See Add Tags for more information.
  • Certain device drivers do not have a list of register names in the DeviceHub Add Tag form. These are Free Tag PLCs. For Free Tag requirements, see Troubleshooting - DeviceHub.

Caution: Because this device belongs to a free tag PLC, the case-sensitive register name must be entered exactly as it is defined in the PLC. The device does not display a Connected status until a tag with a correct register name is created.

Name

Value

R

BOOL

R

SINT

R

INT

R

BIT(INT)

R

DINT

R

REAL

R

LINT