QuickStart Guide
...
Allen-Bradley
Gen 1 Drivers

AB MicroLogix (Gen1)

5min
important this driver was deprecated in litmus edge version 3 5 2 we recommend using the gen 2 ab ethernetip ethernet docid\ q9ichg xpsplyn7hk1v3k review the following information for setting up and configuring the ab micrologix (gen1) driver litmus edge compatible series compatibility parameter compatible items driver type ethernet validated devices/series rockwell automation allen bradley micrologix 1000 rockwell automation allen bradley micrologix 1100 rockwell automation allen bradley micrologix 1200 rockwell automation allen bradley micrologix 1400 rockwell automation allen bradley micrologix 1500 rockwell automation allen bradley slc 5/03 rockwell automation allen bradley slc 5/04 with 1761 net eni rockwell automation allen bradley slc 5/05 ethernet port replaced with gen 2 driver ab ethernetip ethernet docid\ q9ichg xpsplyn7hk1v3k to set up and configure this device in litmus edge, you will need to do the following step 1 set up and configure the plc device step 2 set up the plc device in litmus edge devicehub step 3 configure the list of registers step 1 set up and configure the plc device if the device is configured for ethernet access, find its network parameters otherwise, use plc software on your computer to configure the device for ethernet access refer to the following parameters communication mode port setting 10/100 mbps full duplex/half duplex step 2 set up the plc device in litmus edge devicehub configure the following parameters when you connect a device docid 3eyafppweuvmblcey17sq with this driver update default values to the specific setup of your device parameter value type allen bradley driver ab micrologix (gen1) network address the device address you defined in step 1 port 102 slot number 0 step 3 configure the list of registers when you add tags docid\ xgwokqbtpevii7or82ll0 to the connected device, use the following tag/register mapping table name value type access types address format min address max address description i bit r/w ddddd 0 25515 input bit o bit r/w ddddd 0 25515 output bit s bit r/w ddd 0 255 status bit b3 bit r/w ddddd 0 25515 bit data file (b3) bfn bit r/w fffddddd 100000 25525515 bit data file t4acc int r/w ddd 0 255 timer accumulator (t4) t4pre int r/w ddd 0 255 timer prese (t4) tfnacc int r/w fffddd 1000 255255 timer accumulator tfn pre int r/w fffddd 1000 255255 timer preset cs acc int r/w ddd 0 255 counter accumulator (cs) cs pre int r/w ddd 0 255 counter preset (cs) cfn acc int r/w fffddd 1000 255255 counter accumulator cfn pre int r/w fffddd 1000 255255 counter preset r6 int r/w ddd 0 255 control file (r6) r6 pos int r/w ddd 0 255 control file pointer position (r6) r6 len int r/w ddd 0 255 control file length (r6) rfn int r/w fffddd 0 255255 control file rfn pos int r/w fffddd 0 255255 control file pointer position rfn len int r/w fffddd 0 255255 control file length n7 int r/w ddd 0 255 integer data file (n7) nfn int r/w fffddd 1000 255999 integer data file lfn int r/w fffddd 1000 255999 f8 float r/w ddd 0 255 floating point data file (f8) ffn float r/w fffddd 1000 255999 floating point data file