Delta DVP (Gen1)
Review the following information for setting up and configuring the Delta DVP (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Ethernet |
Validated devices/series |
To set up and configure this device in Litmus Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Litmus Edge DeviceHub
- Step 3: Configure the List of Registers
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.
To configure your device:
Note down the following information and refer to it when needed.
- Launch IPSoft V3.06 software, and then open a new project.
- Search for the device.
Click the device, click the Basic tab, and set up the network parameters.
- Launch COMMGR and configure the driver.
Click Tool > Communication Setting, select the driver, and then click Connect.
Parameter | Value |
---|---|
Type | Delta PLC |
Driver | Delta DVP (Gen1) |
Network Address | The device address you defined in Step 1 |
Port | 502 |
Name | Value Types | Access Types | Address Format |
| Min Address | Max Address |
---|---|---|---|---|---|---|
C_Bit | bit | R/W | DDD | | 0 | 255 |
M | bit | R/W | DDDD | | 0 | 4095 |
S | bit | R/W | DDDD | | 0 | 1023 |
T_Bit | bit | R/W | DDD | | 0 | 255 |
X | bit | R/W | OOO | | 0 | 571 |
Y | bit | R/W | OOO | | 0 | 571 |
T | word | R/W | DDD | | 0 | 255 |
D | word | R/W | DDDDD | | 0 | 11999 |
C_32Bit | word | R/W | DDD | | 200 | 255 |
C | word | R/W | DDD | | 0 | 199 |