QuickStart Guide
...
Industrial Systems Connection ...
Keyence

Keyence KV10 Serial (Gen1)

6min

Review the following information for setting up and configuring the Keyence KV10 Serial (Gen1) driver.

Litmus Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Serial

Validated devices/series

Keyence KV Series 16-80 Visual KV Series

To set up and configure this device in Litmus Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Litmus Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device



Step 2: Set up the PLC Device in Litmus Edge DeviceHub



Parameter

Value

Type

Keyence

Driver

Keyence KV10 Serial (Gen1)

Communication Port

Local Serial connection file path

Baud Rate

9600

Data Bits

8

Parity

Even, Odd, None

Stop Bits

1



Name

Value Type

Access Types

Address Format

Min Address

Max Address

Description

RLY

bit

R/W

DDDDD

0

65535

Relay

DM_Bit

bit

R/W

DDDDDdd

0

999915

Data memory bit

DM

word

R/W

DDDDD

0

9999

Data memory

TM

word

R/W

DDDD

0

9999

Temporary data memory

T

word

R/W

DDDD

0

9999

Timer

T_Curr

word

R/W

DDDD

0

9999

Timer current

T_Preset

word

R/W

DDDD

0

9999

Timer Preset

C

word

R/W

DDDD

0

9999

Counter

C_Curr

word

R/W

DDDDD

0

9999

Counter current

C_Preset

word

R/W

DDDDD

0

9999

Counter Preset