Mitsubishi FX3G ASCII Ethernet (Gen1)
Review the following information for setting up and configuring the Mitsubishi FX3G ASCII Ethernet (Gen1) driver.
Compatibility parameter | Compatible items |
Driver type | Ethernet |
Validated devices/series | MELSEC-F |
To set up and configure this device in Litmus Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Litmus Edge DeviceHub
- Step 3: Configure the List of Registers
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.
To configure your device:
Note down the following information and refer to it as needed.
- Connect the device to your pc using USB and launch the GX Works 2 v1.560J software.
- Click Online > Read from PLC.
- Select PLC series.
- Set up the connection.
- Click Connection Test.
- From the Navigation panel, click Parameter > PLC Parameter > Ethernet Port.
- From the Navigation panel, click Connection Destination > connection1.
- Double-click PLC Module , click Search for FXCPU on network, and then select the target device.
- Click Connection Test.
Parameter | Value |
Type | Mitsubishi |
Driver | Mitsubishi FX3G ASCII (Gen1) |
Network Address | The device address you defined in Step 1 |
Port | 5001 |
Name | Value Types | Address Format | Min Address | Max Address | Description |
X | bit | DDD | 0 | 255 | Input Relay |
Y | bit | DDD | 0 | 255 | Output Relay |
M | bit | DDDD | 0 | 7999 | Internal Relay |
T | bit | DDD | 0 | 511 | Timer Contacts |
C | bit | DDD | 0 | 255 | Counter Contacts |
SM | bit | DDDD | 8000 | 8511 | Source Int. Relays |
S | bit | DDDD | 0 | 4095 | Step Relays |
R | word | DDDDD | 0 | 32767 | File Register |
SD | word | DDDD | 8000 | 8511 | Service Data Register |
CV2 | word | DDD | 200 | 255 | Counter Value |
D | word | DDDD | 0 | 7999 | Data Registers |
CV | word | DDD | 0 | 199 | Counter Value |
TV | word | DDD | 0 | 511 | Timer Value |