Mitsubishi FX3U Serial (Gen1)
Review the following information for setting up and configuring the Mitsubishi FX3U Serial (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Serial |
Validated devices/series | MELSEC-F |
To set up and configure this device in Litmus Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Litmus Edge DeviceHub
- Step 3: Configure the List of Registers
To configure your device:
Note down the following information and refer to it as needed. Device: Mitsubishi Fx3U-16M Communication I/F: RS232. Refer to the following figure.
- Launch GX Works2 v1.560J software, click Create a Project, and then click Connection 1 in the navigation panel.
- Set up communication parameters, and then click Connection Test.
Parameter | Value |
---|---|
Type | Mitsubishi |
Driver | Mitsubishi FX3U Serial (Gen1) |
Communication Port | Local Serial connection file path |
Data Bits | 7 |
Baud Rate | 9600 |
Parity | Even, Odd, None |
Stop Bits | 1 |
Name | Value Types | Address Format | Min Address | Max Address | Description |
---|---|---|---|---|---|
X | bit | OOO | 0 | 500 | Input Relay |
Y | bit | OOO | 0 | 500 | Output Relay |
M | bit | DDDD | 0 | 7999 | Auxiliary Relay |
T | bit | DDD | 0 | 511 | Timer Relay |
C | bit | DDD | 0 | 255 | Counter Relay |
SM | bit | DDDD | 8000 | 8511 | Special Relay |
S | bit | DDDD | 0 | 4095 | State Relay |
R | word | DDDDD | 0 | 32767 | Extended Register |
SD | word | DDDD | 8000 | 8511 | Special Data Register |
CV2 | word | DDD | 200 | 255 | Counter Memory |
D | word | DDDD | 0 | 7999 | Data Register |
CV | word | DDD | 0 | 199 | Counter Memory |
TV | word | DDD | 0 | 511 | Timer Memory |
Z | word | D | 0 | 7 | Index Register |