Parker ACR9000 Ethernet (Gen1)
Review the following information for setting up and configuring the Parker ACR9000 Ethernet (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Ethernet |
Validated devices/series |
To set up and configure this device in Litmus Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Litmus Edge DeviceHub
- Step 3: Configure the List of Registers
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.
To configure your device:
Note down the following information and refer to it when needed. Device: Parker ACR9000 Ethernet Communication I/F: Ethernet. Refer to the following figure.
- Launch the V6.4.2.1014 software and create a project according to device model.
- Click the device in the Navigation pane, set up the device IP, and then click Connect.
Parameter | Value |
---|---|
Type | Parker |
Driver | Parker ACR9000 Ethernet (Gen1) |
Network Address | The device address you defined during Step 1 |
Port | 5006 |
Name | Value Types | Address Format | Min Address | Max Address |
---|---|---|---|---|
P_Low16bit | bit | DDDDDdd | 0 | 9999915 |
P_High16bit | bit | DDDDDdd | 0 | 9999915 |
P_Int32 | int32 | DDDDD | 0 | 99999 |
P_Float | float | DDDDD | 0 | 99999 |