QuickStart Guide
...
Industrial Systems Connection ...
Parker

Parker ACR9000 Ethernet (Gen1)

6min

Review the following information for setting up and configuring the Parker ACR9000 Ethernet (Gen1) driver.

Litmus Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Ethernet

Validated devices/series

To set up and configure this device in Litmus Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Litmus Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.

To configure your device:

  1. Note down the following information and refer to it when needed. Device: Parker ACR9000 Ethernet Communication I/F: Ethernet. Refer to the following figure.

    Reference image of device
    Reference image of device
    
  2. Launch the V6.4.2.1014 software and create a project according to device model.
  3. Click the device in the Navigation pane, set up the device IP, and then click Connect.

Step 2: Set up the PLC Device in Litmus Edge DeviceHub



Parameter

Value

Type

Parker

Driver

Parker ACR9000 Ethernet (Gen1)

Network Address

The device address you defined during Step 1

Port

5006



Name

Value Types

Address Format

Min Address

Max Address

P_Low16bit

bit

DDDDDdd

0

9999915

P_High16bit

bit

DDDDDdd

0

9999915

P_Int32

int32

DDDDD

0

99999

P_Float

float

DDDDD

0

99999