Siemens S7-Advanced (Gen1.3)
9 min
review the following information for setting up and configuring the siemens s7 advanced (gen1 3) driver to review a use case for this driver, see use the siemens s7 browse agent docid\ r1ovrljqfz4oepv1yz3zq litmus edge compatible series compatibility parameter compatible items driver type ethernet validated devices/series s7 300 https //new\ siemens com/global/en/products/automation/systems/industrial/plc/simatic s7 300 html s7 400 https //new\ siemens com/global/en/products/automation/systems/industrial/plc/simatic s7 400 html s7 1200 https //www siemens com/global/en/products/automation/systems/industrial/plc/s7 1200 html s7 1500 https //new\ siemens com/global/en/products/automation/systems/industrial/plc/simatic s7 1500 html replaced with gen 2 driver siemens s7 docid\ pfzdu23os0catqgbkryay to set up and configure this device in litmus edge, you will need to do the following step 1 set up and configure the plc device step 2 set up the plc device in litmus edge devicehub step 3 configure the list of registers step 1 set up and configure the plc device if the device is configured for ethernet access, find its network parameters otherwise, follow the steps below to configure your device note down the following information and refer to it when needed device siemens s7 cpu1212c ac/dc/rly communication i/f profitnet refer to the following figure launch the primary setup tool set up the pg/pc interface using either software or the pc control panel select the network adapter, making sure the pc and the device are on the same subnet browse the siemens devices on the network, select the device, and then set up the network parameters launch the tia portal v14 software and create a project file with the correct device model and version click the accessible devices icon and search for the devices in the same subnet segment right click the device, and select properties set up the network parameters the following settings are applicable for siemens s7 1200 and siemens s7 1500 only the changes must be made when the tia portal is offline, and then downloaded to the plc click protection & security > connection mechanisms in order to read the data block data, uncheck the optimized block access option select profinet interface > advanced options > port and set the partner port to any partner step 2 set up the plc device in litmus edge devicehub parameter value type siemens driver siemens s7 advanced (gen1 3) network address the device address you defined in step 1 port 102 slot 1 name value type address format min address max address i bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 q bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 m bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 pe bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 pa bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 mk bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string ddddd 0 40957 db bit, byte, char, sint, word, int, counter, timer, dword, dint, real, lreal, lword, lint, string dddddd 0 327677 export tags as pdf you have the option of exporting tags as a pdf file export tags with simatic manager to export tags with simatic manager start simatic manager and open the project file right click the target data block , and then select print > object contents save the contents of the data block as a pdf file export tags with the tia portal to export tags with the tia portal launch the tia portal v14 software and open the project file open the data block you want to export from the toolbar, select project > print save the contents of the data block as a pdf file