Yaskawa MP2300 Ethernet (Gen1.3)
3 min
review the following information for setting up and configuring the yaskawa mp2300 ethernet (gen1 3) driver litmus edge compatible series compatibility parameter compatible items driver type ethernet validated devices/series yaskawa mp2300 series https //www yaskawa com/products/motion/machine controllers/mp series/mp2300 to set up and configure this device in litmus edge, you will need to do the following step 1 set up and configure the plc device step 2 set up the plc device in litmus edge devicehub step 3 configure the list of registers step 1 set up and configure the plc device if the device is configured for ethernet access, find its network parameters otherwise, use motionworks iec 2 express 4 5 0 78 software on your computer to configure your device for ethernet access step 2 set up the plc device in litmus edge devicehub parameter value type yaskawa driver yaskawa mp2300 ethernet (gen1 3) network address the device address you defined in step 1 port 44818 input 101 output 111 name value type address format min address max address input word ddd 0 512 output word ddd 0 512 input bit bit ddddd 0 51215 output bit bit ddddd 0 51215