QuickStart Guide
...
Industrial Systems Connection ...
Emerson

FB107 Ethernet

7min

Review the following information for setting up and configuring the FB107 Ethernet driver.

Litmus Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Ethernet

Validated devices/series

To set up and configure this device in Litmus Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Litmus Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, use software on your computer to configure the device for Ethernet access.

Step 2: Set up the PLC Device in Litmus Edge DeviceHub



Parameter

Value

Type

Emerson

Driver

FB107 Ethernet

Network Address

The device address you defined in Step 1

Network Port

4000

Operator ID

LOI

Password

Enter your password

Device Address

240

Device Group

240

Host Address

239

Host Group

1

Next Request Delay

0

Response Timeout

3000

Optimizations

Disable or Enable



Name

Value Types

OP

JSON, HEX

PT

HEX, AC3, AC7, AC10, AC12, AC20, AC30, AC40, INT8, INT16, INT32, UINT8, UINT16, UINT32, FL, DOUBLE, TLP, TIME, DT6

History

JSON

Alarms

JSON

Events

JSON



Supported Opcodes

  • 0 - Obtain a general update of the current state for the physical input/output (I/O) points and the standard application-oriented points
  • 6 - System Configuration
  • 7 - Read Real-time Clock
  • 8 - Set Real-time Clock
  • 17 - Set an operator identification code for the communications port through which communications are occurring
  • 103 - Determine the current version of firmware residing in the ROC, as well as other device-specific information
  • 120 - Send current pointers for the Alarm and Event Logs
  • 121 - Request alarm data from the Alarm Log in the ROC
  • 122 - Request up to 10 events from the Event Log in the ROC
  • 123 - Read User Template Data. Up to seven template parameters may be requested.
  • 126 - Request the ROC unit’s minute data for a specified history point
  • 130 - Request a specified number of hourly or daily data values for a specified history point
  • 167 - Request Single Point Parameters
  • 180 - Request Parameters
  • 181 - Write Parameters

Supported Point Types

  • 0-5
  • 8
  • 12-17
  • 19-23
  • 25-28
  • 43-48
  • 55
  • 80
  • 86
  • 88
  • 89
  • 93
  • 94
  • 98
  • 117
  • 118
  • 120
  • 121
  • 122