Mitsubishi Q02 02H Serial (Gen1)

6min

Review the following information for setting up and configuring the Mitsubishi Q02 02H Serial (Gen1) driver.

Litmus Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Serial

Validated devices/series

MELSEC-Q

To set up and configure this device in Litmus Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Litmus Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device



To configure your device:

  1. Note down the following information and refer to it as needed. Device: Mitsubishi Q02CPU Communication I/F: RS232. Refer to the following figure.

    Reference image of device
    Reference image of device
    
  2. Launch GX Works2 v1.560J software, click Create a Project, and then click Connection 1 in the navigation panel.
  3. Set up communication parameters, and then click Connection Test.

Step 2: Set up the PLC Device in Litmus Edge DeviceHub



Parameter

Value

Type

Mitsubishi

Driver

Mitsubishi Q02-02H Serial (Gen1)

Communication Port

Local Serial connection file path

Data Bits

8

Baud Rate

115200

Parity

Even, Odd, None

Stop Bits

1



Name

Value Type

Address Format

Min Address

Max Address

Description

X

bit

DDDD

0

9999

Input Relay

Y

bit

DDDD

0

9999

Output Relay

M

bit

DDDDD

0

65535

Internal Relay

SM

bit

DDDD

0

2047

 

L

bit

DDDDD

0

32237

Latch Relay

F

bit

DDDDD

0

32237

Annunciator

V

bit

DDDDD

0

32237

Edge Relay

B

bit

DDDDD

0

32237

Link Relay

TS

bit

DDDDD

0

25471

Timer Contact

TC

bit

DDDDD

0

25471

Timer Coil

SS

bit

DDDDD

0

25471

Retentive Timer Contact

SC

bit

DDDDD

0

25471

Retentive Timer Coil

CS

bit

DDDDD

0

25471

Counter Contact

CC

bit

DDDDD

0

25471

Counter Coil

SB

bit

DDDDD

0

32237

Special Link Relay

S

bit

DDDD

0

8191

Step Relay

DX

bit

DDDD

0

8191

Direct Input

DY

bit

DDDD

0

8191

Direct Output

D

word

DDDD

0

9999

Data Register

W

word

DDDD

0

8191

Link Register

SW

word

DDDD

0

8191

Special Link Register

TN

word

DDDDD

0

25471

Timer Current Value

SN

word

DDDD

0

25471

Retentive Timer Current Value

CN

word

DDDDD

0

25471

Counter Current Value

SD

word

DDDD

0

2047

 

R

word

DDDD

0

9999

File Register

ZR

word

DDDDDD

0

999999

File Register

Z

word

DD

0

20

Index Register