Manage
7 min
the manage tab for an edge device enables you to stop and restart specific services enable and configure how frequently litmus edge manager polls the edge device for metrics change the token for direct access to the litmus edge api update the device from a specific version of litmus edge reboot the device download a support bundle for the device stop and restart services in the service tab, optionally start and stop the ssh service and restart device management, authentication, licensing, and nats server services edge device metrics sync interval edge device metrics sync controls how often lem polls connected edge devices for metrics data adjusting the interval lets you balance reporting frequency against network and performance constraints a shorter interval provides more granular visibility into edge device behavior a longer interval reduces network load in bandwidth limited environments sync interval priority the sync interval can be configured at three levels device, project and instance by default, lower level settings take priority the device sync setting overrides the project setting for that device the project sync setting overrides the instance setting for all devices in the project you can also override these priority settings here at the device level by choosing to use the project's metrics sync settings (see manage docid\ boofh2bjolfpger0qymmf ) at the project level by choosing to use the instance's metrics sync settings (see management docid\ vzynhousltjeto0f1afa1 ) note edge device metrics sync settings is available for litmus edge manager version 2 26 1 and later set the edge device metrics sync interval the default interval is 30 seconds with a valid range of 30 to 604,800 seconds (1 week) do any of the following use the enable edge device metrics sync toggle to enable or disable synchronization of metrics update the sync interval for the device by providing a new value in enable edge device metrics sync to instead use the interval defined by the project, select use the project's edge device metrics sync settings api change the token for direct access to litmus edge api see tokens docid\ cs7yxwaz7wylgne0xpsrx to create an api token when creating the api token, you cannot make it read only from the litmus edge user interface software view the list of downloaded update files for the edge device from the action menu , you have the following options manually upgrade the edge device from the update file delete the update file reboot reboot the edge device support download support bundle files for the edge device